Shutdown
11.1 Temporary decommissioning
44
Operator’s Manual | BS-2 | 5100056271 | 07/2022 | [en]
11 Shutdown
11.1 Temporary decommissioning
Information
Further information and detailed descriptions, see Maintenance on
page 33.
Storage requirements
• Store dust-free and dry.
• Do not store outdoors.
• Protect from direct sunlight.
• Observe storage temperature, see Technical Data on page 47.
• Store in a locked place that is not accessible to children.
If the machine is stationary for more than 1 month, perform the following
measures:
Entire machine • Clean thoroughly.
• If necessary, rectify all defects.
• Check for leaks, rectify any defects if necessary.
Fuel tank Drain fuel completely.
Engine • Check engine oil level, fill engine oil if necessary.
• Check and clean air filter.
• Clean fuel filter.
If the machine is shut down for more than 6 months, contact a service
partner.
11.2 Final shutdown
If the machine is no longer in use and is shut down for good, all operating
fluids must be drained.
Have the machine professionally dismantled and disposed of by a state-
approved recycling company.
Professional disposal of this machine avoids negative effects on human
health and the environment, helps with the targeted treatment of pollut-
ants and makes it possible to recycle valuable raw materials.