Operation
T01006GB.fm 23
6.4 Starting the engine with the safety starting crank
1. Turn the throttle control lever to the load position 1/2 - 3/4.
2. Turn the decompression lever (2) all the way to „f“. At this point
automatic decompression lever engages with an audible click, and
the engine is ready to start.
3. Put the ignition key into ignition switch (25) and turn it clockwise into
operating position (the charge control lamp (27) lights up and the
buzzer will be heard).
4. Check to see that the safety starting crank is in good shape and
clean! Broken handle pipes, worn cranking bolts, etc. must be
replaced! Lightly grease the gliding area located between the safety
starting crank and the guide bush (protective casing).
* Stand sideways to the engine.
* Always grasp the handle pipe (h) with both hands.
f