Operation
T01006GB.fm 30
6.9 Stopping the engine
Never switch off the engine with the automatic decompression (2) as
this inevitably results in damage to the valve drive and decompression
mechanism.
1. Move the throttle control lever (8) to the stop.
2. Turn the ignition key to the stop position and then pull it out once the
engine has stopped. The control lamp will extinguish and the
acoustic alarm will turn off.