Maintenance
T01007GB.fm 38
7.5 Battery
7.5.1 Check acid level:
1. Remove battery cover.
2. Check acid level, if necessary top up with distilled water.
3. Secure battery cover.
Make sure the positive battery terminal cover is correctly in place
before proceeding to install the battery cover. Check to see that the
gas venting hose does not have any kinks!
Protect hands end eyes against the acid!
Note: Only replace defective batteries with original Wacker batteries.
Standard batteries are not suitable for the high vibration loads.
4. When changing the battery:
* Removal: First disconnect negativ, then positive terminal of
battery.
* Assembly: First connect positive, then negative terminal of
battery.
When using starting sprays etc., see chapter operation.