EasyManua.ls Logo

Wacker Neuson DPU 6055 - Exciter Oil Level Check and Filling

Wacker Neuson DPU 6055
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
T01007GB.fm 40
7.7 Exciter
7.7.1 Check oil level:
1. Position vibration plate horizontally.
2. Open filler bore (40).
3. The oil level must reach the start of the thread of the filler bore (40).
4. If necessary, pour in oil (see Technical Data) through filler bore (40)
(use funnel 0,75 l).
5. Close filler bore (40). (torque setting = 100 Nm)
Oil

Related product manuals