7-30 BA E19 en* 1.0 * E19_10_700.fm
7 Maintenance
Fuel-filling pump status indicators
Information
Refueling stops in the following cases:
Push button B is pressed and held for a longer period.
The maximum refueling time of 10 minutes was exceeded.
Due to an error message or a full fuel tank.
LED
Green Yellow Red Status
On On On Standby
Flashes Off Off Voltage too low
On Off Off Pump switched on
On Off On Pump conveys fuel
On Off Flashes quickly Contact a Wacker Neuson service center
On Off Flashes slowly Contact a Wacker Neuson service center
On On Off Refueling completed
On Flashes Off
Not enough fuel in the fuel hose (at the beginning of refu-
eling)
Not enough fuel in the barrel (at the end of refueling)
Flashes Flashes Off Contact a Wacker Neuson service center
Off Flashes Flashes Contact a Wacker Neuson service center