4.11 Starting the Machine - LTN 6K-V, LTN 8K-V
Requirements
Before starting checks completed. See Before Starting
NOTICES
Do not use evaporative starting fluids (for example, ether) to start the engine.
Do not start the engine under load.
Procedure
Perform the procedure below to start the machine.
1. Rotate the key (q) counter-clockwise to the glow plug position (GL).
The glow plug indicator (n) will illuminate.
The glow plug indicator will turn off when the engine is preheated.
NOTICE: Cranking the engine longer than 20 seconds could cause damage.
f If the engine does not start, return the key to the “OFF” position and wait 1
minute for the starter to cool before proceding.
2. Immediately rotate and hold the key to the start (ST) position until the engine
starts then release the key.
3. Allow the engine to warm up before operating the lights.
Note: If the oil does not reach operating pressure within 30 seconds, the engine
will stop. You must return the key to the “OFF” for 30 seconds before restarting the
engine.
wc_gr009978
ON
OFF
GL
ST
a c
q n
b