4.17 Automatic Shutdown
Description
This machine is equipped with a low oil, high temperature automatic shutdown
system. This system will automatically interrupt the fuel supply to the engine if the
oil pressure drops too low or the engine exceeds normal operating temperatures.
Resetting
after
automatic
shutdown
If an automatic shutdown occurs, the engine will stop. Return the key switch to the
off position to reset the system.
See Troubleshooting or contact Wacker Neuson Product Support if automatic
shutdown frequently occurs.
4.18 Stopping the Machine - LTN 6K/8K-V
NOTICE: Turn off the lights before stopping the engine. Failure to do so will
damage the electrical system.
Procedure
Perform the procedure below to stop the machine.
1. Disconnect all loads from the machine.
2. Turn the circuit breakers (a, b, c) off.
3. Rotate the key to the “OFF” position.