EasyManua.ls Logo

Wacker Neuson WM 90

Wacker Neuson WM 90
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disassembly Procedures WM 90 Repair
wc_tx000389gb.fm 46
7.5 Removing Governor Lever, Carburetor, Speed Control Lever
See Graphic: wc_gr001890
7.5.1 Mark the hole in which the governor spring (a) is attached and remove
the spring.
7.5.2 Loosen the M6 bolt (b) and remove the governor lever (c).
7.5.3 Remove the governor rod (d) and the rod spring (e), and if necessary,
bushing (f).
7.5.4 Remove the carburetor flange (g), the gaskets (h), the carburetor (i).
7.5.5 Remove the bolts (j) securing the insulator (k) and remove the
insulator and gasket (m).
7.5.6 Remove the M6 pivot bolt (n) and washer (o) and remove the speed
control lever (p).
7.5.7 Also remove return spring (q) and spacer (r).
7.5.8 Remove the two M6 x 8 flange bolts (s) and remove the base plate (t).

Table of Contents