EasyManua.ls Logo

WAGNER AC 4600 - Starting-Up; General Rules for Handling the Spray Gun

WAGNER AC 4600
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
AC 4600 Pro
B_02700
OPERATING MANUAL
EDITION 02/2009
PART NO. DOC394871
5.3 STARTING-UP
Trigger safety catch in on
(safe) position
Air
Material
5.3.1 GENERAL RULES FOR HANDLING THE SPRAY GUN
Observe general safety instructions in chapter 2.
CAUTION
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
SIHI_0005_GB
SIHI_0065_GB
WARNING
Unintentional putting into operation!
Risk of injury
Before all work on the unit, in the event of work interruptions and
functional faults:
Switch off the energy/compressed air supply.
Relieve the pressure from the spray gun and unit.
Secure the spray gun against actuation.
By functional faults: Identify and correct the problem, proceed
as described in chap„Trouble shooting“.

Table of Contents