EasyManua.ls Logo

WAGNER EvoMotion 20-30 - Assembling the Pump

WAGNER EvoMotion 20-30
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
B_04105
2
3
6
5
1
4
8
B_04106
2
1
3
5
7
6
4
8
OPERATING MANUAL
VERSION 11/2015 ORDER NUMBER DOC2333553
6.4 ASSEMBLING THE PUMP
Notice
This pump can be used as part of a spraying system for Airless or
AirCoat applications. Individual supplement components for
this pump can be found in the WAGNER Accessories Catalogue,
or can be put together with the Spraypack Con gurator. The
nozzles must be selected according to the gun instructions. In
the case of spraypack orders, the pumps(1) are already pre-
mounted on a trolley (6) or on a frame at the factory.
Procedure:
1 Mount pump (1) on frame, trolley (6) or wall mount.
2 Mount an AirCoat system with the pressure regulator(7)
and secure the thread at the air inlet to the pump (1)
with Loctite 270.
3 Mount suction system (5).
4 Mount the return valve (8) for pressure relief or product
circulation.
5 Mount return tube (4) or return hose
6 Connect the high-pressure hose (2) and gun (3) in
accordance with the gun operating manual.
Example:
Airless system
Example:
AirCoat system