30
B_00304
R max < 1 M:
OPERATING MANUAL
VERSION 11/2015 ORDER NUMBER DOC2333553
6.5 GROUNDING
Grounding scheme (example)
Paint tank
Work piece
Conveyor
Spraying stand
Floor, static dissipative
Note for the sprayer
Safety shoes and gloves, if used,
must be static dissipative.
Heavy paint mist if grounding is insu cient!
Danger of poisoning.
Insu cient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Cable cross sections
Pump 4 mm; Conveyor 16 mm;
Product tank 6 mm; AWG 10 Booth 16 mm;
Spraying stand 16 mm;
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic sparks.
Clean the piston pump only with a damp cloth.
Ground all device components.
Ground the work pieces to be coated.
WARNING