1. Check the level of separating agent in the separating agent cup every day, and top
up if necessary.
2. Check and clean the product lter every day or as required.
3. Every shut down should be carried out as laid down in Chapter 8.1.3!
4. Check hoses, pipes, and couplings every day and replace if necessary.
If the pump has to be emptied for maintenance work, proceed according to
Chapter8.2.5.
The service manual is available in German and English.
For order number see Chapter 1.3.
8.2.3 REGULAR MAINTENANCE WORK
8.2.4 FILLING WITH SEPARATING AGENT
Pour the supplied separating agent into the intended opening.
Filling level: 1 cm; 0.4 inch under the lling opening.
Separating agent: See accessories.
Notice
Maximum permissible inclination of pump for moving,
transportation etc. after lling it with separating agent ± 30°.
The pump must be vertical during operation.
Piston pump dry run!
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
Ensure that the separating uid tank is lled with su cient separating uid. Filling
level 1 cm; 0.4 inch under the tank edge.
NOTICE