7.5 PRESSURE RELIEF/WORK INTERRUPTION
If the system has been used with 2K products:
Pressure relief of the product
1. Close the spray gun.
2. Close ball valve (2).
3. Relieve the system pressure, either by opening the gun or by opening the return
valve (3).
4. Close and secure gun.
5. Open and close the return valve (3) to completely depressurize the system.
Pressure relief of the air (in case of longer work interruptions)
1. Carry out pressure relief of the product (as mentioned above).
2. Ensure that the ball valve (2) is closed.
3. Pull back the ring on the safety valve (10) and hold it there until the pressure in the
air motor has been equalized.
Hardened working material in the spraying system when 2K product is processed!
Destruction of pump and injection system.
Follow the manufacturers processing rules, particularly regarding the pot life.
Flush thoroughly before the end of the pot life.
The pot life is decreased by warmth.
NOTICE