24 Device Description WAGO ETHERNET Accessories 852
852-111 Industrial ECO Switch
Manual
Version 1.3.1
4.4.4 Environmental Conditions
Table 11: Technical data - environmental conditions
Surrounding air temperature, operatio)
-40+70 °C
max. +60 °C (UL)
Surrounding air temperature, operation,
DNV GL (Temperature class D)
-25+70 °C
Surrounding air temperature, storage
-40+80 °C
UL 508 Use
Pollution degree
Indoor
2
Relative humidity (without
condensation)
5 … 95 %
Vibration resistance
Acc. to IEC 60068-2-6
Shock resistance
Acc. to IEC 60068-2-27
EMC-1 immunity to interference
Acc. to EN 61000-6-2
EMC-1 Emission of interference
Acc. to EN 61000-6-4
Standard Compass Safe Distance 0.3
Degree deflection
1000 mm
Steering, Standby, Emergency
Compass Safe Distance 1.0 Degree
deflection
650 mm

Table of Contents

Other manuals for WAGO 852 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGO 852 Series and is the answer not in the manual?

WAGO 852 Series Specifications

General IconGeneral
Model852 Series
CategorySwitch
Ports8, 16
Data Rate10/100 Mbps
Power Supply24 VDC (typically)
Mounting TypeDIN rail
Switch TypeManaged

Related product manuals