2.4 Low air temperature
In standard conditions the following minimum inlet air temperatures apply:
Gas mode:
Low load + 5ºC
High load -10ºC
Diesel mode:
Starting + 5ºC
Idling - 5ºC
High load - 10ºC
For further guidelines, see chapter Combustion air system design.
NOTE
Air Waste Gate (AWG) is needed when suction air temperature is below +5°C.
2-10 DBAE248994