10 11
3
If the system has called for a regeneration that will occur at the preset time of regeneration, the words
“REGEN TODAY” will appear on the display.
If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons
per minute going through the system.
2. REGENERATION MODE: Typically a system is set to regenerate at a
time of no water usage. If there is a demand for water when the system is
regenerating, untreated water will be delivered. When the system begins
to regenerate, the display will change to include information about the
step of the regeneration process and the time remaining for that step to be
completed. The system runs through the steps automatically and will reset
itself to provide treated water when the regeneration has been completed.
3. MANUAL REGENERATION: Sometimes there is a need to regenerate
before the control valve calls for it. This may be needed if a period of heavy
water use is anticipated or when the system has been operated without salt.
• To initiate a manual regeneration at the next preset regeneration time,
press and release
regen. The words “REGEN TODAY” will flash
on the display to indicate that the system will regenerate at the next
regeneration time (set in Programming, steps 4 and 5). If you pressed
the regen button in error, pressing the button again will cancel the
command.
• To initiate a manual regeneration immediately, press and hold the
regen button for three seconds. The system will begin to regenerate
immediately. This command cannot be cancelled.
Once a manual regeneration is initiated, the unit will go into the FILL position. This position allows water to enter the brine
tank until it reaches the proper level. Once this position is complete, you will notice a 240 Minute (4 hours) SOFTENING
position. This 4-hour window allows the salt to dissolve and achieve proper brine strength. During these FILL and SOFTENING
positions, you will have softened water available for use. Once the unit advances to the BACKWASH position and
subsequent positions thereafter (see Start Up Instructions for regeneration sequence), the water softener will deliver water, but
it will be untreated.
IMPORTANT: With the Dry Salt Storage Feature, the brine tank will refill 4
hours before the actual regeneration occurs. You may experience a small amount
of noise for a short period of time at 10:00 p.m. (with typical setting) on the
night that regeneration is to occur. This noise is only the brine tank filling and at
no time during this process will you be without treated water.
4. POWER LOSS AND BATTERY REPLACEMENT: The AC transformer comes
with a 15 foot power cord and is designed for use with the control valve; the
transformer should only be used in a dry location.
In the event of a power outage, the control valve will remember all settings and
time of day. If an extended power outage occurs, the control valve will keep time
of day until the battery is depleted. When the battery becomes depleted, the only
item that needs to be reset is the time of day and will be indicated by the time of
day flashing. All other settings are permanently stored in the nonvolatile memory.
If a power loss occurs and the time of day flashes, this indicates that the battery
is depleted. The time of day should be reset and the non-rechargeable battery
BACKWASH
8:22
REGENERATION MODE
MANUAL REGENERATION
REGEN TODAY MON
GPM
2:408
PM
REGEN TODAY and TIME OF DAY
will flash alternately if a regeneration
is expected tonight.
4
DAYS TO A REGEN
GPM
3
8
CAPACITY REMAINING
GPM GAL
1600
8
BATTERY REPLACEMENT