PRE-INSTALLATION INSTRUCTIONS FOR DEALERS
The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and
salt dose refill time.
The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration,
before installation:
For the installer, the following must be used:
• Program Installer Settings ... Hardness, Day Override (preset to 6 days), and Time of Regeneration (preset to
2 a.m., with brine tank refill to occur four hours prior; see Operating Displays and Instructions for more details)
• Read Normal Operating Displays
• Set Time of Day
• Read Power Loss & Error Display
For the homeowner, please read operating displays and instructions.
WATER SOFTENERS:
During operation, the normal user display is time of day and gallons per minute.
Flow Rate, Capacity Remaining and Days to a Regeneration are optional displays but are not normally used. Each of
these can be viewed by pressing
next to scroll through them. When stepping through any programming, if no buttons are
pressed within 5 minutes, the display returns to a normal user display. Any changes made prior to the 5 minute time out
are incorporated.
To quickly exit any Programming, Installer Settings, etc., press
set clock. Any changes made prior to the exit are
incorporated. If desired, two regenerations within 24 hours are possible with a return to the preset program. To do a
double regeneration:
1. Press the
regen button once. “REGEN TODAY” will flash on the display.
2. Press and hold the regen button for three seconds until a regeneration begins.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset.