8 9
1. Set time of day:
1 2
3 4
PROGRAMMING PROCEDURES
NOTE: The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated
after the hardness is entered.
STEP 1 – Press
next and + simultaneously for 3 seconds.
STEP 2 – HARDNESS: Set the amount of hardness in grains per gallon (default 20) using the + or — buttons.
The allowable range is from 1 to 150 in 1 grain increments.
Note: If a resin media is used in the softener, increase the grains per gallon if soluble iron is present
(1ppm = 4 gpg). This display will show “–nA– (not available)” if “FILTER” is selected or if
“AUTO” is not factory set.
Press
next to go to step 3. Press regen if you want to exit.
STEP 3 – DAYS BETWEEN REGENERATION (DAY OVERRIDE): The manufacturer has factory set 6 DAYS
as the default. This is the maximum number of days between regenerations. If this is set to “OFF”,
regeneration initiation is based solely on gallons used. If any number is set (allowable range from 1 to
28), a regeneration initiation will be called for on that day even if a sufficient number of gallons were
not used to call for a regeneration.
Set Day Override using + or — buttons (6 is recommended):
• set number of days between regeneration (1 to 28); or
• set to “OFF”
NOTE: This valve has the capability of regenerating up to six times in one
day. This can be observed by using the — button to toggle below once a day
regeneration (see example to right). These settings are typically used in twin
system configurations or in commercial settings.
Press
next to go to step 4. Press regen if you need to return to the previous step.
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends.
If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
STEP 1 – Press
set clock.
STEP 2 – CURRENT TIME (HOUR): Set the hour of the day using + or — buttons. AM/PM toggles after 12.
Press
next to go to step 3.
STEP 3 – CURRENT TIME (MINUTES): Set the minutes using + or — buttons. If it is desired to back up to the
previous step press
regen button once. Press next to go to step 4.
STEP 4 – CURRENT DAY: Set the day of the week using + or — buttons. Pressing
next will exit set clock and
return to the general operating display (page 10).
Example: Indicates unit set
to regen 4 times in one day.