EasyManua.ls Logo

WaterLogic WL Cube - Page 20

WaterLogic WL Cube
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.
Use a Phillips-head screwdriver to remove the two screws at the rear of the
machine that hold the top panel in place.
7.
Remove the Top Panel by placing your hands on the top as
shown in the picture and push it backwards and then lift it up to
remove.
8.
Insert your finger into the round hole of the lever and pull the
lever up to the vertical position.
9.
Pull the lever straight up to remove the filter assembly (some
slight force may be required
10.
Unscrew the filter body from the filter head by turning the base
in an anti-clockwise direction.
11.
Remove the filter cartridge from the filter head by pulling it out as shown.
12.
Add the required amount of sanitizing fluid to the empty filter housing.
CUBE Operating, Installation, and Service Manual Page 20 - Revision: 6-23-2015

Related product manuals