REPLACING QUARTZ SPIRAL
1.
Turn off both the Green Heater/Compressor Switch
and the Red Power Switches located on back of unit
I = ON, O= Off
2.
Unplug power to unit.
3.
With a Phillips Head Screwdriver, remove the two
screws at back of the Top Cover as shown.
4.
Remove top panel by placing your hands on the top
and pushing the top panel towards the rear.
Lift and remove as shown.
5.
With a Phillips Head Screwdriver, remove the two
screws on the Left Side Panel as shown. Remove
Left Side Panel.
Remove the two screws on the Right Side Panel as
shown.
Remove Right Side Panel.