Watlow EZ-ZONE
®
PM Integrated Controller 7 Chapter 1 Overview
EZ-ZONE
®
PM Integrated Model 1/16 DIN With Limit, System Diagram
Without Communications Card (Slot B)
Note:
Number of inputs and outputs and various combinations of the same will vary
depending upon part number; see ordering matrix for more detail.
EZ Key
Programmable Event
Digital Output (or Input) 5 & 6
(optional) none, switched dc
Digital Input (or Output) 5 & 6
(optional) none, switch, volts dc
Limit Controller
Board
(optional)
Slot B
Input
Functions
Output
Functions
- None
- Limit reset
- Idle set point
- Tune
- Alarm clear, request
- Force alarm
- Silence alarm
- Manual/auto mode
- Control outputs off
- Remote set point
enable
- Lock keypad
- TRU-TUNE+
®
disable
- Loop & alarms off
- Profile disable
- Profile hold/resume
- Profile start
- Profile start/stop
- Restore user settings
- Event inputs
Output Status
5
1
3
2
4
Indicates Zone
Address
Indicates I/O
Status
Zone
Address
Analog Input 1
none, Thermocouple, RTD (100Ω,
1kΩ), Thermistor 5kΩ, 10kΩ, 20kΩ,
40kΩ) Process (V, mV, mA) or 1k
Potentiometer
Output 1
none, switched dc/open collector, 5A
mechanical relay (form C), process
(V, mA), or 0.5A SSR (form A)
Output 2
none, 15A NO-ARC, switched dc,
5A mechanical relay (form A), or
0.5A SSR (form A)
PID
Controller
(Optional -
Ramp/Soak max 4
files, 40 steps)
Slots A
(Optional)
Input Sensor
off, heat, cool
alarm, retransmit,
duplex, event
off, heat, cool
alarm, event
off, heat, cool
alarm, retransmit,
duplex or event
Limit
off, heat, cool
alarm, event
Modbus
Address 1 - 247
Standard Bus
Zone Address
1 - 16
Supervisory &
Power Board
Slot C
EIA-485 Communication
Standard Bus
(optional Modbus RTU)
RUI, EZ-ZONE
Controllers, PLC, PC
or HMI
Output 3
none, switched dc/open collector, 5A
mechanical relay (form C), process
(V, mA), or 0.5A SSR (form A)
Output 4
5A mechanical relay (form A)
Analog Input 2
none, CT, Thermocouple, RTD (100
Ω, 1kΩ), Thermistor 5kΩ, 10kΩ,
20kΩ, 40kΩ) Process (V, mV, mA)
or 1k Potentiometer
Input Sensor
If Limit, this output must
be Limit
6
Integrated PID and Limit Controller
• Reduces wiring time and termination complexity compared to connecting separate products
• Reduces panel space
• Reduces installation costs
• Increases dependability with backup control sensor operation
• Increases user and equipment safety for over-under temperature conditions