EasyManua.ls Logo

Watlow ez-zone pm - Page 46

Watlow ez-zone pm
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Watlow EZ-ZONE
®
PM Integrated Controller 43 Chapter 5 Operations Page
Operations Page
Display
Parameter name
Description
Range Default
Parameter
Appears in
Menu When
Modbus Rela-
tive Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Data
Type
&
Read/
Write
No Dis-
play
EZ-Key/s (1 to 2)
Event Status
View this event input
state.
[`off] Off (62)
[``on] On (63)
Off - - - - Instance 1
Map 1 Map 2
1368 1608
Instance 2
Map 1 Map 2
- - - - 1628
0x6E (110)
3 to 4
5
140 uint
R
[LiM]
[oPEr]
Limit Menu
[`LL;S]
[ LL.S]
Limit (1)
Low Set Point
Set the low process
value that will trig-
ger the limit.
-1,999.000 to
9,999.000°Forunits
-1,128.000 to
5,537.000°C
0.0°For
units
-18.0°C
Limit Sides
(Setup Page)
is not set to
High.
Instance 1
Map 1 Map 2
684 724
0x70 (112)
1
3
38 float
RWES
[`Lh;S]
[ Lh.S]
Limit (1)
High Set Point
Set the high process
value that will trig-
ger the limit.
-1,999.000 to
9,999.000°Forunits
-1,128.000 to
5,537.000°C
0.0°For
units
-18.0°C
Limit Sides
(Setup Page)
is not set to
Low.
Instance 1
Map 1 Map 2
686 726
0x70 (112)
1
4
39 float
RWES
No Dis-
play
Limit (1)
Limit State
Clear limit once limit
condition is cleared.
Off (62)
None (61)
Limit High (51)
Limit Low (52)
Error (225)
- - - -
Always if
9
th
digit of
model part
number is
an L.
Instance 1
Map 1 Map 2
690 730
0x70 (112)
1
6
- - - - uint
R
No Dis-
play
Limit (1)
Limit Clear Request
Clear limit once limit
condition is cleared.
Clear (1131) 0
Always if
9
th
digit of
model part
number is
an L.
Instance 1
Map 1 Map 2
680 720
0x70 (112)
1
1
- - - - uint
W
[Mon]
[oPEr]
Monitor Menu
[C;MA]
[C.MA]
Monitor (1 to 2)
Control Mode Ac-
tive
View the current con-
trol mode.
[`off] Off (62)
[AUto] Auto (10)
[MAn] Manual (54)
Always Instance 1
Map 1 Map 2
1882 2362
Instance 2
Map 1 Map 2
1952 2432
0x97 (151)
1 to 2
2
- - - - uint
R
[`h;Pr]
[ h.Pr]
Monitor (1 to 2)
Heat Power
View the current
heat output level.
0.0 to 100.0% 0.0
Heat algo-
rithm is not
set to Off.
(Setup Page)
Instance 1
Map 1 Map 2
1904 2384
Instance 2
Map 1 Map 2
1974 2454
0x97 (151)
1 to 2
0xD (13)
- - - - float
R
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with
other interfaces.
* Available with PM4, PM8 and PM9 models only
R: Read
W: Write
E: EE-
PROM
S: User
Set

Table of Contents

Other manuals for Watlow ez-zone pm

Related product manuals