Watlow EZ-ZONE
®
PM Integrated Controller 42 Chapter 5 Operations Page
Operations Page
Display
Parameter name
Description
Range Default
Parameter
Appears in
Menu When
Modbus Rela-
tive Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Data
Type
&
Read/
Write
[``o;u]
[ o.v]
Process Value (1 to 2)
Output Value
View the value of
this function block's
output.
-1,999.000 to
9,999.000°Forunits
-1,128.000 to
5,537.000°C
0.0 Always Instance 1
Map 1 Map 2
- - - - 3322
Instance 2
Map 1 Map 2
- - - - 3392
0x7E (126)
1 to 2
0x16 (22)
- - - - float
R
No Dis-
play
Process Value (1 to 2)
Output Error
View reported cause
for Process output
malfunction.
None (61)
Open (65)
Shorted (127)
Measurement error
(140)
Bad calibration data
(139)
Ambient error (9)
RTD error (14)
Fail (32)
Math error (1423)
Not sourced (246)
Stale (1617)
Can't process (1659)
None Instance 1
Map 1 Map 2
- - - - 3332
Instance 2
Map 1 Map 2
- - - - 3402
0x86 (134)
1 to 2
0x1B (27)
- - - - uint
R
[`dio]
[oPEr]
Digital Input/Output Menu
[`do;S]
[ do.S]
Digital Output (5 to 6)
Output State
View the state of this
output.
[`off] Off (62)
[``on] On (63)
Direction
(Setup Page,
Digital In-
put/Output
Menu) is set
to Output.
Instance 1
Map 1 Map 2
1012 1132
Offset to next
instance equals
+30
0x6A (106)
5 to 6
7
90 uint
R
[`do;S]
[ do.S]
Digital Output (7 to 12)
Output State
View the state of this
output.
[`off] Off (62)
[``on] On (63)
Direction
(Setup Page,
Digital In-
put/Output
Menu) is set
to Output.
Instance 1
Map 1 Map 2
- - - - 1132
Offset to next
instance equals
+30
0x6A (106)
7 to 12
7
140 uint
R
[`ei;S]
[ Ei.S]
Digital Input (5 to 6)
Event Status
View this event input
state.
[`off] Off (62)
[``on] On (63)
Direction
(Setup Page,
Digital In-
put/Output
Menu) is set
to Input Volt-
age or Input
Dry Contact.
Instance 1
Map 1 Map 2
1328 1568
Offset to next
instance equals
+20
0x6E (110)
1 to 2
5
140 uint
R
[`ei;S]
[ Ei.S]
Digital Input (7 to 12)
Event Status
View this event input
state.
[`off] Off (62)
[``on] On (63)
Direction
(Setup Page,
Digital In-
put/Output
Menu) is set
to Input Volt-
age or Input
Dry Contact.
Instance 1
Map 1 Map 2
- - - - 1648
Offset to next
instance equals
+20
0x6E (110)
5 to 10
5
140 uint
R
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with
other interfaces.
* Available with PM4, PM8 and PM9 models only
R: Read
W: Write
E: EE-
PROM
S: User
Set