6 Operation
WU017834 Rev. 05 July 2023 Wayne Fueling Systems | Dover Fueling Solutions 65
6.10.2 Arming or Disarming Smart Secure Access (SSA) Using Maintenance Mode
NOTE! When Smart Secure Access (SSA) is enabled using Function 56.01, the system can be temporarily
disarmed for service by entering Maintenance Mode and then opening the bezel doors. Keep the
doors open as long as is needed for service. When finished, close and secure the doors. The switch
will automatically re-arm after one minute and the dispenser will return to idle operation.
IRC Button Sales Display Volume Display Price Display
Press ENTER PASS 1
Type the corresponding
PASSWORD
Press ENTER
PASS 2
Type the PASSWORD
again
Press ENTER
iGEM software version Date F - -
Press 56
Press ENTER
- - - - - - - F 56
Press 1
Press ENTER
- - - - - - - 0 56.01
To Arm:
Press #
Press 1
Press ENTER
To Disarm:
Press #
Press 0
Press ENTER
- - - - - - -
- - - - - - -
1
0
56.01
56.01
Saving the new setting
Press ENTER - - - - - - - F 56
Press 0
Press ENTER
- - - - - - - F 00
Press ENTER - - - - - - - 1 0.00
Press #
Press 3
Press ENTER
- - - - - - - 3 0.00
Press ENTER CHAnGE StorEd
This has enabled the security switch. After one minute
the switch will be armed. Pressing Enter dur-
ing the one minute period will display “Secure OFF”. After one minute, press ENTER and the display
will show “Secure ON”. The procedure is now complete. The bezel should not be opened.
NOTE! Opening the door anytime after this point will constitute a security breach. At the time a breach occurs,
the annunciator will sound a constant alarm tone and the display will show “Closed”. To clear the
breach: open, close and secure the doors then enter Maintenance Mode. The switch will automatically
re-arm after one minute and the dispenser will return to the idle operation.