Programming Classic Unit
11
3 Programming Classic Unit
3.1 Programming level 2, Classic Card TCC 5.25
3.2 Programming level 3 at 29 °C, Classic Card TCC 5.25
Display Setting Default Min Max Unit
b Selection of blower speed A 0 A
F Selection of function mode 3 1 5
U Reading of voltage supply 0 Volt
1C Choice compressor 1 ON/OFF 1 0 1
d Dehumidification cycle when system turned off (0 = non ac-
tive; 1 = 1 cycle per 24h; 2 = 2 cycles per 24h ; 3 = 3 cycles per
24h)
003
t Time to display table F 5 1 5 20 sec.
Display Setting Default Min Max Unit
0 Lower cut-out value in cool mode for evaporator temperature 0 -4 15 °
1 Cut-in value in cool mode for evaporator temperature 7 2 18 °
2 Higher cut-out value in heat mode for evaporator temperature 45 30 50 °
3 Cut-in value in heat mode for evaporator temperature 38 27 47 °
4 Calibration evaporator temperature 0 -55 55 1/10°
5 Time for display standby 15 5 99 minutes
6 Time delay for first compressor start 1 1 20 seconds
7 Calibration of air temperature 0 -55 55 1/10°
8 Calibration of voltage under 50 Hz 0 -30 50
9 Time delay for compressor restart after end of cycle cut-out 2 1 99 minutes
A Calibration of voltage under 60 Hz 0 -30 50
B Program version v5.2*
C Mode choice for pump exit 0 0 1
D Minimum voltage for pump exit 12 12 18 Volt
E Maximum voltage for pump exit 18 12 18 Volt
F Mode choice for water valve exit 1 0 1