Digital Control Panel operation and settings
7
1.2 Entering programming menu level 2
• When security CODE is activated, push FUNCTION when unit is in operation till CODE appears in the display.
• Set security CODE by pushing UP or DOWN and confirm with FUNCTION (Default = 64).
• In case security CODE is not activated you will have direct access.
• Scroll through settings by pushing FUNCTION, values can be set by UP or DOWN keys and confirmed by FUNCTION for
next line.
• To leave this menu push ON/OFF, MEMO will be shown shortly and new settings will be memorised.
1.3 Entering programming menu level 3
• Set setpoint temperature on 15 °C or 29 °C and switch off the controller.
• Push UP and DOWN simultaneously till display lights up.
• Set security CODE when activated by pushing UP or DOWN and confirm with FUNCTION (Default = 64).
• Scroll through settings by pushing FUNCTION, values can be set by UP or DOWN keys and confirmed by FUNCTION for
next line.
• To leave this menu push ON/OFF, MEMO will be shown shortly and new settings will be memorised.