EasyManua.ls Logo

Weber 3000 - Page 29

Weber 3000
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WWW.WEBER.COM
®
29
PREPARING TO USE YOUR BARBECUE
C) To check for leaks, wet fittings with the soap and water
solution, using a spray bottle, brush or rag. If bubbles
form, or if a bubble grows, there is a leak. Apply the
soap and water solution to the following connections:
a) Manifold-to-regulator hose connection (7).
b) Valve-to-outside burner tube gas line connection
(8).
c) Valve-to-inside burner tube gas line connection
(9).
d) Regulator-to-cylinder connection (10).
e) Regulator hose-to-regulator connection (11).
m WARNING: If there is a leak at
connections (7, 8, 9, 10 or 11), turn
off the gas. DO NOT OPERATE THE
BARBECUE. Contact the Customer
Service Representative in your area
using the contact information on our
web site. Log onto www.weber.com
®
.
D) When leak checking is complete, turn gas supply off at
the source and rinse connections with water.
NOTE: Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.
Now you are ready to use your barbecue.
8
9
7
10 11

Table of Contents

Other manuals for Weber 3000

Related product manuals