6 WWW.WEBER.COM
CONSIDERATIONS FOR LOCATING
YOURBARBECUE
Any enclosure in which the appliance is used shall comply
with one of the following:
An enclosure with walls on all sides, but at least one
permanent opening at ground level and no overhead
cover (1).
Within a partial enclosure that includes an overhead
cover and no more than two walls (2).
Within a partial enclosure that includes an overhead
cover and more than two walls, the following shall
apply (3):
(a) at least 25% of the total wall area is completely
open; and
(b) at least 30% of the remaining wall area is open and
unrestricted.
In the case of balconies, at least 20% of the total of the
side, back and front wall areas shall be and remain
open and unrestricted.
1
2
Open side at
least 25% of
total wall area
30% or more in total of the remaining
wall area is open and unrestricted
Both ends open
Open side at
least 25% of
total wall area
30% or more in total of the remaining
wall area is open and unrestricted
3
BARBECUE LOCATION REQUIREMENTS

Table of Contents