SIDE BURNER MAINTENANCE
.4', WARNING: All gas controls and supply valves should be in
the "OFF" position,
Make sure black wire is connected between the igniter and electrode.
Make sure white wire is connected between the igniter and grounding clip.
Spark should be a white/blue color, not yellow.
1) Igniter Wire
2) Ground wire
3) Burner
Side Burner Grate ----
Side Burner cap
Side Burner Ring & Head
Igniter Electrode
Control Knob ---=
Igniter
PROBLEM CHECK CURE
Rotisserie burner does not light. Did you hold the burner control knob in and Try to relight burner by holding burner control knob in and continue holding in until
hold in for 20 seconds until after burner 20 seconds after burner has ignited.
Bgnited?
Did you wait to see the entire ceramic surface When relighting burner by holding burner control knob in, wait to see the entire
become alight before counting 20 seconds? ceramic surface become alight before counting 20 seconds?
Did you repeatedly use the snap ignition until After waiting five minutes for gas to clear, try repeatedly using the snap igniter until
the burner ignited? the burner ignites (refer to "Lighting the Rotisserie BurneC').
Does the igniter work (Do you see a spark Try manually lighting the burner (refer to "Lighting the Rotisserie Burner"). Call
when you repeatedly use the snap igniter? customer service.
General Symptoms: The excess flow safety device, which is part of To reset the excess flow safety device turn all burner control knobs and the cylinder
Burner does not light. -or- Burner has the barbecue to cylinder connection, may have valve to "OFF". Disconnect the regulator from the cylinder. Turn burner control
a small flickering flame activated, knobs to "START/HI". Wait at least 1 minute. Turn burner control knobs to "OFF".
Reconnect the regulator to the cylinder. Turn cylinder valve on slowly. Refer to
"Lighting Instructions".
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our
web site. Log onto www.weber.com%
a i * A* A* A _ t =l:] =lZi(_[I] = _i