Faults and Alarms
14-10 | CFW501
14
P0054 – Temperature in the IGBTs Last Fault
P0064 – Temperature in the IGBTs Second Fault
P0074 – Temperature in the IGBTs Third Fault
Adjustable
Range:
-20 to 150 ºC Factory
Setting:
Properties: ro
Access groups
via HMI:
READ
Description:
These parameters indicate the IGBTs temperature at the moment of the occurred fault.
P0055 – Logical Status Last Fault
P0065 – Logical Status Second Fault
P0075 – Logical Status Third Fault
Adjustable
Range:
0000h to FFFFh Factory
Setting:
Properties: ro
Access groups
via HMI:
READ
Description:
It records the inverter logical status of P0680 at the moment of the occurred fault. Refer to section 7.3 CONTROL
WORD AND INVERTER STATUS on page 7-10.
P0080 – Last Fault in “Fire Mode”
P0081 – Second Fault in “Fire Mode”
P0082 – Third Fault in “Fire Mode”
Adjustable
Range:
0 to 9999 Factory
Setting:
0
Properties: ro
Access groups
via HMI:
READ
Description:
These parameters indicate the last three faults that occurred on the inverter while the "Fire Mode" was active.