23 / 116
o Format: X2X1X0. X2X1X0=100: External EMG (emergency stop input) was
not used.
o Range: -
o Value: 100
P2-21 Digital output pin DO4 function setting
o Description: DO4 pins are pin No.1 and No.26, which are used for Z-axis
clamping position braking signals.
o Unit: -
o Format: X2X1X0
X2=1: Set DO4 output to the NO contact a. X2=1: Set DO4 output to
the NC contact b.
X1X0=08: Set pin No.1 and No.26 to BK+ and BK- respectively.
o Range: -
o Value: 108
P2-22 Digital output pin DO5 function setting
o Description: DO5 pins are pin No.28 and No.27, which are used for servo
alarm signals.
o Unit: -
o Format: X2X1X0
X2=0: Set DO5 output to the NC contact b.
X1X0=07: Set pin No.28 and No.27 to ALRM+ and ALRM-
respectively.
o Range: -
o Value: 007
P2-51 Servo enablement SON setting
o Description: Servo enablement SON setting
o Unit: -
o Format: -
o Range
0: Servo motor enablement must be triggered by digital signals.
1: Servo motor is automatically enabled after powered on if there is no
alarm.
o Value: 0 (1 when SON signal cables are unavailable)
3.4.1.1.9 Delta ASDA-A2
The parameters and descriptions are shown below:
P0-02 Drive status display
o Description: Pulse detection is used in WEIHONG control systems to check
to see if correct pulses are sent and determine if there is electric interference.
o Unit: -
o Format: -
o Range: -
o Value: 02
P1-00 External pulse input format
o Description: External pulse input format
o Unit: -
o Format: ZYX
X=2: The external pulse input format is pulse + direction, negative
logic
Z=1: negative logic