EasyManua.ls Logo

WEIHONG NK105 G2F - Page 70

Default Icon
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specialized Concentrated Focused
58References
Parameter
Meaning
Setting range
REFP Dir
The direction of rough positioning in backing to
machine origin
Positive; Negative
Retract Dist
The additional motion distance after fine positioning
stage in backing to machine origin, to move out of the
machine origin signal sensitive zone
0~10000 mm
Sign of BK REF
Whether to eliminate the sign of backing to machine
origin after E-stop
Yes: Eliminate
No: Not eliminate
CAUTION
If you can ensure that the axis position will not deviate after E-stop, you can set the parameter “Sign of BK REF”
to “No”, so you can continue machining without backing to machine origin after E-stop is obviated. Otherwise,
you need to set this parameter to “Yes” to ensure machining accuracy.
Spindle Parameters
Parameter
Meaning
Setting range
Spindle Set
ON/OFF Delay
The wait time for the spindle to reach normal rotary
speed or stop completely after turned ON or OFF
0~60000 ms
Spindle Speed
The spindle speed during auto machining
0~[Max. Spdl Speed]
Max. Spdl Speed
Max. spindle speed
Spindle speed~999999
mm/min
Parameters Related with Y Rotary Axis
Parameter
Meaning
Setting range
Y AsRotaryAxis
Whether Y axis is set as rotary axis
Yes: Valid; No: Invalid
Rotary Y Pulse
The pulse equivalent of Y axis when it is set as
rotary axis
0~100 mm/p
mm As Unit
It sets the measure unit for the rotary axis.
Yes: in mm
No: in deg
Rev. WorkRadius
The length of Y axis in CAM programming is the
value of workpiece radius × 
parameter changes with the radius of workpiece.
0~1000000mm
Rotary Takeoff
The takeoff speed of the rotary axis
0~1000000 mm/s
Rotary Y Acc.
The acceleration of the rotary axis, with unit as
rad/s
2
0.001~100000.0 rad/ s
2
Max. RotaryVel.
Max. rotary speed
0.06~6000000 r/min
Parameters Related with Lubrication Setting
Parameter
Meaning
Setting range
EnableAutoLube
Whether to open lubrication pump automatically at
Yes: Valid

Related product manuals