Error
Problem
Solution
(Heater off on
request)
draw was <1A
on the heater
circuit.
Ensure you counter hold the rear bolt of the element connections before tightening
the front nut on the element.
Lastly replace SRB
E117: see E115
MAGNETRON
OVERHEAT
Old firmware.
The safety
thermostat
circuit (12vdc)
has opened for
>1 second
during a cook
cycle.
Download the up to date firmware from merrycheftechnical.com and load on to
the oven
Warning Error Codes generated during operations:
Error
Problem
Solution
E079: TOUCH
PREWARNING
RELEASE
(Constant key
press)
Pressure
registered for
>5 seconds,
but <15
seconds on
QTS screen
Check touch screen overlay, see E087
E080: TOUCH
PREWARNING
(Constant key
press)
Pressure
registered for
>5 seconds on
QTS screen
Check touch screen overlay, see E087
E083: SRB
VERSION
Incompatible
SRB version
Replace SRB, check part numbers.
E084: INVALID
DATE
Invalid date at
start up
Set correct date and time
E087:
CONSTANT KEY
PRESS
DETECTED
Pressure
registered for
>15 seconds
on QTS screen.
Oven will stop
working.
Ensure the firmware is up to date with the most recent update which can be found at
www.merrycheftechnical.com
Ensure there is no debris between the QTS screen and the overlay film.
Ensure the QTS assembly is installed correctly
Replace the overlay and clean the glass of the touchscreen, execute a screen calibration.
Lastly, replace the QTS.
E088: SUPPLY
VOLTAGE
ERROR
Mains supply
voltage is ±10%
from the
nominal range
across all
models (200V
240V), i.e.,
<180VAC or
>264VAC
mains supply
Check mains supply voltage and compare with displayed voltage in visual view.
If similar the fault lies within the kitchen mains supply.
If significantly different, check all connections from the mains supply to the SRB. If
correct, replace SRB.
E099: FILTER
OVERRIDE
Operator
selected
continue when
filter was
removed (filter
microswitch
was open
circuit)
Check filter magnets, filter microswitch & connections