6.6 Replacing a magnetron
Component
Tools required
Hammer or similar tool
PZ2 Pozidriv screwdriver
M8 hex socket wrench
Torque wrench
Discharge Tool
Requirements
Check that the following requirements have been met:
§ The appliance has been disconnected from the power supply and protective measures have been taken to ensure
the power cannot be switched on again.
§ The appliance is cool.
§ The top, left and right panels of the casing of the appliance have been removed.
§ The high voltage capacitors are discharged before commencing work.
The magnetron(s) is/are located on top of the cavity and
is/are fixed to the cooling duct and the cavity roof.
The 2000W e2s variant comprises two magnetrons located
on the left and right hand sides of the cooling duct.
The cooling duct covers one side of the
magnetron where the magnetron is
attached to the cavity roof with two screws.
The image shows a single magnetron 1000W
e2s variant.
The outlet of the cooling duct carries heat to the back of the
oven and is covered by a grille.
The outlet comprises a sheet metal frame containing holes
corresponding to the positions of Pozidriv screws securing the
cooling duct to the magnetron.
Use these holes for guiding the Pozidriv screwdriver.