Merrychef eikon
®
e2s service and repair manual
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
6 Replacing components
Back to contents >
Mains cable entering the interior
(the mains cable gland is fitted to the cable inlet of the oven at the rear of the oven base)
Catalytic Converters
See section 6.14 for convection fan motor assembly removal to access the catalytic converters.
Voltage Switching Relay(s)
The voltage switching relay(s) is located on the rear right hand side of the oven base by two M5.5 hex nuts. The 2000W e2s
variant comprises two relays in the same location, one for each HV transformer.
The upper catalyst is fitted using four M7 hex
flange nuts, tightened to 2.1 Nm.
Note: remove the storage cable ties before
installing a new replacement catalyst.
The lower catalyst, only installed on 2000W
models, is again fitted using four M5.5 hex flange
nuts, tightened to 2.1 Nm.