6 Replacing components
Back to contents >
Magnetron
<1W
Speaker
2.
1
E107
Communication fault between QTS & SRB
HV Transformer
Pri
0.6W*
Cavity Thermocouple
1.
7
E108
Missing or corrupt QTS PM
HV Transformer
Sec
57W*
LV Transformer
2.
1
E109
Missing or corrupt SRB PM
Capacitor
10MW
Steam Vent Pipe
2.
1
E110
Incompatible SRB firmware
Front Panel
2.
1
E111
Cavity sensor open circuit
Maximum Cavity Temperature
Mains Filter to Bracket
2.
8
E112
SRB temperature sensor failure
275
o
C
Fuse Holder
1.
0
E113
Magnetron(s) on without request. >1A
VDF to Bracket
2.
8
E115
Safety circuit open during microwave cook
cycle
Cook Plate Studs
8.
0
E116
Heater off on request. <1A
Heating Element
2.
1
E117
No longer used, see E115
* see section 3.1 ‘Technical data, checks and verification’ for non-EU model specific readings where they differ.