that
the
battery
is
being
overcharged
and
will
damage
the
battery
if
left
unchecked.
The
voltage
regulator
is
most
likely
at
fault.
When
the
battery
is
being
charged
(having
electrical
loads
placed
upon
it
and
no
charg
ing
current
applied),
it
is
normal
for
the
needle
to
indicate
between
11.4
and
12.6
volts.
Electrical
System
Troubleshooting
Trouble
ON
switch
depressed,
electric
fuel
pump
not
energized
possible
Cause
1.
Battery
switch
or
power
not
on
2.
20
amp
circuit
breaker
tripped
Remedy
1.
Check
switch
and/or
battery
connections.
2.
Reset
breaker
if
it
opens
again,
check
preheat
solenoid
cir-
cuit
and
"run"
circuit
for
shorts
to
ground.
No
ignition,
cranks,
1.
Overspeed
module
1.
Reset
circuit
by
de-
pressing
stop
switch.
does
not
start
tripped
Starts,
stops
when
ON
switch
released
2.
Fuse
blown
3.
Lack
of
fuel
2.
Check
fuses~
replace
if
necessary.
3.
Check
for
fuel
to
generator
set.
Check
fuel
lift
pump.
4.
Choke
faulty
4.
Check
to
see
that
it
is
not
jammed.
Should
be
closed
if
engine
is
cold.
5.
Coil
faulty
5.
Check
coil.
6.
Distributor
faulty
6.
Check
distributor,
cap
and
wires.
7.
Wiring
faulty
7.
Check
wires
and
con-
1.
Safety
circuit
switch
or
wiring
faulty
2.
Fuse
blown
3.
Overspeed
module
faulty
85
nections
for
shorts,
breaks
and
corrosion.
1.
Inspect
all
wiring
for
shorts,
corrosion
or
loose
connections.
Check
operation
of
switches.
2.
Check
fuses.
3.
Check
module.