Trouble
Engine
stops
possible
Cause
Remedy
1.
Low
oil
pressure
or
2.
Check
oil,
fresh
water
overheated
and
sea
water
cooling.
2.
Low
oil
pressure
switch
fails
to
close
2.
Check
for
satisfactory
operation
with
switch
bypassed.
3.
High
water
or
3.
Same
as
above.
exhaust
temperature
switches
open
at
too
low a
temperature
4.
Overspeed
module
5.
Switch
and
wiring
4.
Check
engine
speed.
Check
module
for
pro-
per
operation.
5.
Inspect
all
wiring
for
loose
connections
and
short
circuits.
Not
charging
battery
1.
Alternator
drive
or
battery
runs
down
1.
Check
drivebelt
and
its
tension.
Be
sure
alternator
turns
free-
ly.
Check
for
loose
connections.
2.
Oil
pressure
switch
2.
Observe
if
gauges
and
light
are
on
when
engine
is
not
running.
Test
the
normally
open
oil
pressure
switch
by
disconnecting
one
lead.
If
lights
go
out
replace
oil
pressure
switch.
3.
High
resistance
leak
to
ground
3.
Check
wiring.
Insert
sensitive
(0-.25
amp)
meter
in
battery
lines.
(Do
not
start
engine.)
Remove
con-
nections
and
replace
until
short
is
located
4.
Low
resistance
leak
4.
Check
all
wires
for
to
ground
temperature
rise
to
locate
fault.