EasyManua.ls Logo

Westinghouse iGenTent - User Manual

Westinghouse iGenTent
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User
Manual
iGenTent
Generator Running Cover
for Fully Encased Inverter Generators
WeatherProof Your Power
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call
customer service at 855-944-3571.
Question and Answer IconNeed help?

Do you have a question about the Westinghouse iGenTent and is the answer not in the manual?

Summary

IMPORTANT PRODUCT SAFETY

General Safety Precautions

Key safety warnings and cautions for using the GenTent, including proper operation and installation guidelines.

IMPORTANT OPERATING NOTES

GenTent Operating Guidelines

Important notes and tips for proper GenTent operation, setup, and use in various conditions.

ASSEMBLY

1. ASSEMBLE AND INSTALL STRAP MOUNT

Instructions for assembling and installing the initial strap mount for the GenTent.

2. ASSEMBLE THE EXTENDER ARMS

Guide for assembling and positioning the GenTent extender arms for optimal frame support.

3. INSTALL GENTENT FRAME

Steps for installing the main GenTent frame components, including center connector and rods.

4. COVER THE GENTENT

Procedures for attaching the GenTent canopy and electrical apron to the frame.

Quick Release of the GenTent

How to quickly remove the assembled GenTent from the generator for maintenance.

5. INSTALLING THE GENTENT WITH PARALLEL UNITS

Instructions for installing the GenTent on generators operating in parallel.

LIMITED WARRANTY

Warranty Coverage Details

Details on what defects and conditions the warranty includes and excludes.

Warranty Duration and Service Information

Specifies warranty duration and how to obtain service for the GenTent.

GenTent Repair and Replacement Policy

Outlines GenTent's commitment to repair or replace defective parts.

REGISTER YOUR PURCHASE - ACTIVATE YOUR WARRANTY

Summary

IMPORTANT PRODUCT SAFETY

General Safety Precautions

Key safety warnings and cautions for using the GenTent, including proper operation and installation guidelines.

IMPORTANT OPERATING NOTES

GenTent Operating Guidelines

Important notes and tips for proper GenTent operation, setup, and use in various conditions.

ASSEMBLY

1. ASSEMBLE AND INSTALL STRAP MOUNT

Instructions for assembling and installing the initial strap mount for the GenTent.

2. ASSEMBLE THE EXTENDER ARMS

Guide for assembling and positioning the GenTent extender arms for optimal frame support.

3. INSTALL GENTENT FRAME

Steps for installing the main GenTent frame components, including center connector and rods.

4. COVER THE GENTENT

Procedures for attaching the GenTent canopy and electrical apron to the frame.

Quick Release of the GenTent

How to quickly remove the assembled GenTent from the generator for maintenance.

5. INSTALLING THE GENTENT WITH PARALLEL UNITS

Instructions for installing the GenTent on generators operating in parallel.

LIMITED WARRANTY

Warranty Coverage Details

Details on what defects and conditions the warranty includes and excludes.

Warranty Duration and Service Information

Specifies warranty duration and how to obtain service for the GenTent.

GenTent Repair and Replacement Policy

Outlines GenTent's commitment to repair or replace defective parts.

REGISTER YOUR PURCHASE - ACTIVATE YOUR WARRANTY

Overview

The document is a user manual for the GenTent iGenTent Generator Running Cover, designed for fully encased inverter generators. This product, covered by GenTent and Westinghouse, aims to weatherproof portable generators, allowing them to operate safely in various weather conditions.

Function Description:

The GenTent iGenTent Generator Running Cover is a protective enclosure that allows inverter generators to run safely outdoors during inclement weather, including rain, snow, and high winds (up to 70 mph). It creates a stable and strong mounting point for the generator frame, ensuring proper ventilation and protection for the electrical panel and fuel tank. The design accommodates different generator case shapes and exhaust configurations, including those with high exhausts, by allowing for adjustable mounting and a sloped canopy. It also features a refueling door for easy access without removing the cover and an electrical panel apron to keep outlets dry. The system is designed for quick release to facilitate maintenance.

Important Technical Specifications:

  • Generator Compatibility: Suitable for fully encased inverter generators with perimeters up to 124 inches.
  • Weather Resistance: Designed for use in forecast winds up to 70 mph and snow loads up to 18 inches.
  • Mounting System: Utilizes Kevlar® Ratchet Straps, Angle Braces, and Gator Grommets™ for secure attachment to the generator case.
  • Frame Structure: Composed of Fiberglass Frame Rods and a Center Connector.
  • Dimensions (Extender Arms Span): Creates an offset rectangle around the inverter with a width of 23" to 25" and a length of 34" to 36".
  • Materials: Kevlar® Ratchet Strap, fiberglass frame rods, molded plastic components for Angle Braces and Extender Arms, and a canopy material (specific type not detailed but implied to be weather-resistant).
  • Parallel Unit Capability: Can accommodate running smaller 1-2K watt generators in parallel under one canopy with an additional purchase of the "GenTent Inverter Extender Arms Kit."

Usage Features:

  • Easy Installation: The manual provides detailed steps for assembling and installing the strap mount, extender arms, frame, and canopy.
  • Adjustable Fit: Gator Grommets™ have two thicknesses to optimize fit on various generator case shapes. Angle Braces have adjustment teeth with five different positions to allow Extender Arms to move into desired locations.
  • Exhaust Management: Specific instructions are provided for installing on generators with high exhausts to ensure proper venting and prevent exhaust from blowing directly on the canopy. The electrical apron must be positioned at least four inches away from the exhaust.
  • Refueling Door: A dedicated refueling door allows for easy generator refueling without removing the GenTent. Proper sealing of this door is crucial to prevent water seepage.
  • Electrical Panel Protection: An opaque electrical panel apron covers the generator's electrical outlets, ensuring they remain dry.
  • Ventilation: The open corners of the top cap are designed for ventilation.
  • Quick Release: The GenTent can be quickly released and removed as a single assembly for generator maintenance, maintaining its shape due to strap tension.
  • Parallel Operation: The design supports running multiple smaller inverter generators in parallel under a single canopy, requiring specific extender arm configurations.

Maintenance Features:

  • Periodic Snow Removal: During snowstorms, it is recommended to periodically brush away any snow accumulation that blocks the top vent.
  • Disassembly for Storage: While complete disassembly of Extender Arms is not necessary between uses, instructions are provided for disassembling them using a flat-head screwdriver if desired.
  • Customer Support: Users are encouraged to contact customer service for questions or assistance, rather than returning the product to the store. Email, phone, and chat options are available.
  • Warranty: A one-year limited warranty covers defects in materials or workmanship under normal use, with specific exclusions for improper installation, abuse, neglect, or modifications not specified by the manufacturer. The warranty covers repair or replacement of defective components.
  • Product Registration: Users can register their purchase online or by mail to activate their warranty and receive product updates, safety tips, and special offers.

Westinghouse iGenTent Specifications

General IconGeneral
BrandWestinghouse
ModeliGenTent
CategoryPortable Generator
LanguageEnglish

Related product manuals