5.7.12. Signification of the error codes
T Heating element temperature
A Bead up
W Heating
U Change over
R Pressure ramp
t Cooling time
p Cooling pressure
9 Environmental temperature < 0 °C
5.7.13. Copying the internal data on SD - card and deleting internal data (RAM)
Abort and back to basic menu by pressing button <C>.
One step back by pressing buttons <Enter> (keeping pressed) and <->.
Display:
2. line:
WIDOS 4600 SPA
09:43 03.05.2004
Basic menu
Next step by pressing simultaneously buttons <> and <Enter>.
Display:
2. line:
copy
_
By pressing <+> you can copy the data from the internal memory onto the SD-
card.
Only displayed if no card is in the drive:
Display:
2. line:
error SD card
Message appears if there is no SD card in the drive
Confirm the error message by pressing <Enter>.
Next step by pressing button <Enter>.
Display:
2. line:
delete CNC-RAM?
Delete internal memory (RAM) by pressing button <+>.
When pressing button <->, the internal memory (RAM) will not be deleted.
When an error occurs, these error codes