samos Safety System
© 2010 Wieland Electric GmbH | BA000256 | 12/2012 (Rev. I)
7
The coded modules of the samos system
Accordingly to the applications in a samos overall system hard-coded system groups can
be assembled, whose codings are different and whose logical functions are independent
from each other. Every system group of the overall system consists of a distinctly coded
basic module, which can be amended with input modules of the same coding.
Example of one system group
Basic module
Master (SA-BM-S1)
Input module
(SA-IN-S1)
Input module
(SA-IN-S1)
Output module
Bus interconnection
module
System group 1
More safety via coding
In our enhanced
samos
system, every basic module (SA-BM) and every input module (SA-
IN) is hard-coded according to its system group (1-3) and cannot be applied in other
system groups. Equally coded basic modules cannot be stuck together. Modules SA-BM,
and/or SA-IN in combination with
samos
system modules, which have been delivered in
Germany in an overall system with two or more basic modules of the same coding and at
least one input module, prior to the 17th of April in 2012 (till construction level E-01)
mustn't be applied without approval of the patentee of the German patent 100 20 075.
(more information at http://register.dpma.de/DPMAregister/pat/einsteiger?lang=en)
Coding