samos
®
PRO
samos
®
PRO
-Gateways
Manual
Doc. no. BA000970
Last Update: 11/2016 (Rev. F)

Table of Contents

Questions and Answers

  • C
    Cindy PerezAug 3, 2025
    What to do if the SP-COP2-ENI module in Wieland samos PRO COMPACT Gateway does not provide any data?
    • P
      Phillip BaxterAug 3, 2025
      If the SP-COP2-ENI module in your Wieland Gateway doesn't provide data, ensure at least one Ethernet link is established. Set up the Ethernet link on your PC, verify the Ethernet wiring, and check the Ethernet settings in both the PLC and samos-PLAN5+. If Ethernet communication isn't needed, disable the Ethernet connections or PLC interfaces on the SP-COP2-ENI. Also, a duplicate IP address can cause this issue, so correct the IP address and then power cycle the system. This can happen because the module has been configured for data transmission to the PLC, but no Ethernet communication has been established or the communication is faulty or because there is a duplicate IP address detected.
  • C
    carolyn01Aug 18, 2025
    What to do if Wieland Controller has an error?
    • F
      Frank GarciaAug 18, 2025
      If the Wieland Controller encounters an error, perform a power ON reset after resolving the underlying cause of the error. Restarting the control will help clear the error.
  • M
    Maria ClayAug 26, 2025
    Why Wieland Controller inputs show cable break or short-circuit?
    • J
      Jose AlvarezAug 26, 2025
      A cable break or short-circuit to 24V at one or more inputs of the Wieland Controller can occur due to a sequence/synchronous time error at a two-channel input.
  • M
    mmcdanielNov 10, 2025
    Why samosPLAN5+ cannot set up a connection to the samosPRO Wieland samos PRO COMPACT Gateway?
    • C
      Clayton PowellNov 10, 2025
      If samosPLAN5+ cannot establish a connection to the samosPRO Wieland Gateway, first check that the SP-COP2-ENI module has power. Then, verify that the SP-COP2-ENI module is on the same physical network as the PC and that the subnet mask in the PC's TCP/IP settings is correct. To resolve this, switch on the power supply. Check the Ethernet wiring and the network settings of the PC and correct them where necessary. Set the PC to a network address 192.168.1.0 (the delivery state of the SP-COP2-ENI module has the address 192.168.1.4, which may not be used for the PC). Alternatively activate DHCP on the PC and link the SP-COP2-ENI module and the PC to a network, using an active DHCP server. Check the communication settings in samos-PLAN5+. This issue may occur because the SP-COP2-ENI module lac...

Summary

Safety

Qualified persons

Specifies requirements for personnel installing, commissioning, and maintaining gateways.

Proper use

Outlines correct operation, limitations, and prerequisites for samosPRO gateways.

Installation and basic configuration

Installing;removing

Provides step-by-step instructions for mounting and dismounting modules on standard rails.

Electrical installation

Details necessary electrical connections, grounding, and safety precautions.

Configuration of gateways

Modbus TCP gateway

Basic configuration - allocation of an IP address

Details how to assign an IP address for Modbus TCP communication.

Configuration of the Modbus-TCP interface to the PLC - how the data are transferred

Explains data transmission methods between the gateway and the PLC.

PROFINET IO-Gateway

Basic configuration - Assigning a device name and an IP address

Details IP address assignment and device naming for PROFINET IO.

PROFINET configuration of the gateway - how the data are transferred

Explains data transmission methods between the gateway and the PLC for PROFINET IO.

EtherNet;IP gateway

Diagnostics and troubleshooting

Provides solutions for common EtherNet/IP gateway issues and error states.

PROFIBUS DP gateway

PROFIBUS configuration of the gateway - how the data are transferred

Explains data transmission methods between the gateway and the PLC for PROFIBUS DP.

CANopen gateway

Diagnosis and troubleshooting

Provides solutions for common CANopen gateway issues and error states.

EtherCAT Gateway

Diagnostic LEDs on the gateway and troubleshooting

Provides solutions for EtherCAT gateway LED status and troubleshooting.

Wieland samos PRO COMPACT Specifications

General IconGeneral
BrandWieland
Modelsamos PRO COMPACT
CategoryGateway
LanguageEnglish