Installation and operating instructions Wilo-SiBoost Smart (FC) ... Helix V/... Helix VE/... Helix EXCEL 33
5.2 Technichal Data)
Max. flow rate see catalogue/data sheet
Max. delivery head
see catalogue/data sheet
Speed
2800 – 2900 rpm (fixed speed) Helix V
900 – 3600 rpm (variable speed) Helix VE
500 – 3600 rpmn (variable speed) Helix EXCEL
Mains voltage 3~ 400 V ±10 % V (L1, L2, L3, PE)
Rated current
See rating plate
Frequency
50 Hz
Electrical connection
(see installation and operating instructions and wiring diagram of the
control device)
Insulation class
F
Protection class
IP 54
Power consumption P1
See rating plate of the pump/motor
Power consumption P2
See rating plate of the pump/motor
Nominal diameters
Suction/pressure pipe connection
R 1½/ R 1½
(..2 Helix V/VE/EXCEL 4)
(..3 Helix V 4)
R 2/ R 2
(..2 Helix V/VE/EXCEL 6)
(..3 Helix VE/EXCEL 4)
(..4 Helix V 4)
R 2½/ R 2½
(..2 Helix V/VE/EXCEL 10)
(..2 Helix V/EXCEL 16)
(..3 Helix V/VE/EXCEL 6)
(..3 Helix V/EXCEL 10)
(..4 Helix VE/EXCEL 4)
(..4 Helix V/VE/EXCEL 6)
R 3/ R 3
(..2 Helix VE 16)
(..3 Helix VE 10)
(..3 Helix V 16)
(..4 Helix V/VE/EXCEL 10)
DN 100/ DN 100
(..3 Helix VE 16)
(..4 Helix V/VE 16)
(subject to change without prior notice / refer also to the enclosed instal-
lation plan)
Permissible ambient temperature
5 °C bis 40 °C
Permissible fluids
Pure water without settling sediment
Permissible temperature of the fluid
3 °C bis 50 °C
Max. permissible operating pressure
on the pressure side 16 bar (see rating plate)
Max. permissible inlet pressure
indirect connection (however max. 6 bar)
Further data...
Diaphragm pressure vessel
8 L (optional)