30 Installation and operating instructions • Wilo-Yonos MAXO/-D/-Z • Ed.01/2022-08
DANGER
Risk of fatal electrical shock!
There is a risk of fatal injury from electric shock when working on electrical devices.
Work on electrical components may only be carried out by qualified electricians!
Switch off the voltage on all-poles of the pump and secure against unauthorised restart!
Always switch off the power supply from the pump and if necessary SSM!
Due to the presence of dangerous contact voltage, work on the module must not be
started until 5minutes have elapsed!
Check whether all connections (even potential-free contacts) are voltage-free!
The pump may still be live even in voltage-free state. The rotor induces a contact voltage,
which is also present at the motor contacts. Close the existing shut-off valves in front of
and behind the pump!
If the control module/Wilo plug is damaged, the pump must not be put into operation!
In case of impermissible removal of operating elements on the control module, there is a
risk of electrical shock if inner electrical components are touched!
WARNING
Risk of burns when touching the pump/system
Depending on the operating status of the pump and the system (fluid temperature), the entire
pump can get very hot.
Allow the system and pump to cool to room temperature!
9.2 Dismantling/installation
Before any dismantling/installation operation, make sure that the “Shutdown” chapter has been taken into
consideration!
WARNING
Risk of burns when touching the pump/system
Depending on the operating status of the pump and the system (fluid temperature), the entire
pump can get very hot.
Allow the system and pump to cool to room temperature!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo Yonos MAXO and is the answer not in the manual?

Wilo Yonos MAXO Specifications

General IconGeneral
ModelYonos MAXO
CategoryWater Pump
Protection ClassIPX4D
Max. Operating Pressure10 bar
Frequency50/60 Hz
Temperature Range-20°C to +110°C
Energy Efficiency Index (EEI)≤ 0.23
ApplicationHeating, cooling, and solar systems
Operating ModesConstant pressure
Motor ProtectionIntegrated
MaterialsCast iron, stainless steel
Voltage230 V
Ambient TemperatureUp to +40°C
Connection SizeDN 25
Power Supply1~230 V, 3~400 V (depending on the model)

Related product manuals