Maintenance
03801/A1
RT-flex58T-E
Winterthur Gas & Diesel Ltd.
5/ 8
Group Component Work to be carried out Intervals
56121 Exhaust valve
control unit
Random check of piston and slide rod 18 000 Op. h
Replace rail valve (pre-control valve) 30 00036 000 Op. h
Replace filter 18 000 Op. h
58011 Regulating
linkage
Check for free movement, lubricate all movable
parts
3000 Op. h
6
64201 Scavenge air
receiver
Check and clean air flaps 40006000 Op. h
Clean receiver 40006000 Op. h
Check water drain pipings for free passage 15003000 Op. h
Exhaust gas
turbocharger
Wash-cleaning of blower in service (see Operating Manual)
Wash-cleaning or dry cleaning of turbine in
service
(see Operating Manual)
Air filter Check filter half yearly
Cleaning of filter at a p increase of 50%
compared to the shop test value at same engine
load
(see Operating Manual 65101)
as required
65451 Auxiliary blower Clean impeller and casing 24 00036 000 Op. h
Replace ball-bearing 24 00036 000 Op. h
66061 Scavenge air
cooler
Cleaning of scavenge air cooler (air side) in
service at the beginning weekly, later at a p
(pressure drop through SAC) increase of 50%
compared to the shop test value at same engine
load
(see Operating Manual 66061)
as required
Check condensate collector through sight glass
(see Operating Manual 83451)
daily
Check condensate collector for free passage
(see Operating Manual 83451)
15003000 Op. h
Check scavenge air cooler sealing quarterly
Vent daily
Remove scavenge air cooler for general overhaul as required
2013
Inspection and Overhaul Intervals (Guidelines)

Table of Contents