To key (Electric) start Lister ST2
engines:
Ensure the parking brake is in the raised
“ON” position.
Ensure gear lever is in the neutral
position.
Depress and hold down the accelerator.
Pull the control lever outwards and allow it
to rotate anticlockwise so that it abuts
against the top stop and is in a vertical
position (G).
Turn the starter key and release
immediately the engine fires. Do not
motor the engine continuously for more
than 20 seconds.
Release the accelerator pedal.
IMPORTANT: As soon as the engine
reaches normal speed, turn the control
lever clockwise to the horizontal position
so that it abuts the horizontal stop (J).
Cold Starting Below -10
o
C (14
o
F)
A cup and plunger is fitted to the
combustion air intake port on ST engines.
Operate as follows:
Withdraw the plunger (K) and fill one
third of the cup (L) with the same type
of lubricating oil as used in the engine.
Replace the plunger and inject the oil
just before starting the engine.
The device must not be used more than
three times in succession. When hand
starting, turn the engine 20 revolutions
with the fuel on after injecting the oil,
before attempting to start.
To stop engine
Turn the control lever clockwise in the
direction of the arrow (M) and hold it until
the engine stops.
2.6 OPERATION
DRIVING THE DUMPER