Page 16
Winkhaus STV
Operating Manual EAV 0124653 0505
Subject to technical changes
Winkhaus STV GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · Germany · www.winkhaus.de · stv@winkhaus.de
Frame element:
Drill a hole with a of 6 mm [0.236“] through the
door frame.
Pass the cable through the door frame.
Fasten the element with the fitting screw [1] having a
of 4 x 25 mm [0.984“].
Sash element
Drill a hole of 13 mm [0.512“] through the
fitting groove up to the glass groove.
CAUTION!
The bore hole must be burr-free. The spring
must be under a slight pre-tension even with
the door being closed.
Pass the cable with the plug for the motor box
through the door sash.
Insert the end of the spring into the hole in the door
sash.
Fasten the element in the fitting nut by using the
fitting screws [2] having a of 4 x 25 mm [0.984“].
Install the cable for example within the glass groove
towards the motor box; install the rest of the cable
for example within the hollow cell.
3.2. Cable transition KÜ-T STV (plug-in)
Installation sequence:
NOTICE!
Provide a cable reserve of about 3 - 5 cm [1.181 - 1.969“] for the spring
tension behind the sash element of the cable transition.
Establish the plug-in connection after putting the door on its hinges.
Fix the plug with the fitting screw [3] having a of 4 x 25 mm [0.984“].
CAUTION!
Recommendation: Do not mount the second retaining screw [3]
before having installed the door frame into the wall reveal.
CAUTION!
Insulate the wires not used!
3. Installation