14
User Manual WMF950S
Safety
Installation location
The device must be placed and levelled on ahorizontal, sturdy,
water-resistant, and heatproof base.
The device must not be cleaned using awater jet. The device
must be installed where it is protected against water spray.
The device must not be located on asurface that is sprayed or
cleaned with awater hose, steam jet, steam cleaner, or similar
devices.
Do not use the coffee machine outdoors.
Constant water connection
(optional, with constant water model)
3/8inch hose connector with water mains tap, and dirt filter
with 0.08mm mesh size, on-site. At least 0.2MPa (2bar)
supply pressure at2l/min. Maximum 0.6MPa (6bar).
Important. If the customer’s on-site flow pressure exceeds
0.6MPa (6bar), then apressure reducer must absolutely be
connected upstream and set to amaximum of 0.6MPa (6bar).