49
User Manual WMF950S
Software | System
Manual insert
Options: • active
• inactive
Default value:
active
active The pad is displayed when “Ready to operate”.
Portioner calibration
✻ Check if the correct grinding degree is set
Portioner calibration determines the correct amount of
ground coffee for agrinder.
This calibration is necessary when changing the type of
beans and after acertain period of use, due to wear on
the grinding discs.
The goal is that the set value should match the amount
of ground coffee dispensed.
This is the only way to ensure that the amount of
grounds called for in the beverage recipe is correctly
dispensed.
Set required grinding degree (customer-specific
requirements)
✻ Fill the bean hopper
✻ Use the coffee measuring spoon
✻ Touch Grind
The portioner calibration begins.
✻ Follow the instructions on the display
Grounds disposal through the counter (optional)
Options: • active
• inactive
Default value:
inactive
Portioner calibration
DS_05_05_03