49
User Manual WMF950S
Software | System
Manual insert
Options: active
inactive
Default value:
active
active The pad is displayed when “Ready to operate”.
Portioner calibration
Check if the correct grinding degree is set
Portioner calibration determines the correct amount of
ground coffee for agrinder.
This calibration is necessary when changing the type of
beans and after acertain period of use, due to wear on
the grinding discs.
The goal is that the set value should match the amount
of ground coffee dispensed.
This is the only way to ensure that the amount of
grounds called for in the beverage recipe is correctly
dispensed.
Set required grinding degree (customer-specific
requirements)
Fill the bean hopper
Use the coffee measuring spoon
Touch Grind
The portioner calibration begins.
Follow the instructions on the display
Grounds disposal through the counter (optional)
Options: active
inactive
Default value:
inactive
Portioner calibration
DS_05_05_03